• Register
  • Login
  • Subscribe
  • Contact Us

Supply and Installation of Power Supply, Uninterruptable for New Block Redevelopment Projects of Queen Man- Hospital and Cranlham Hospital

HongkongTenders notice for Supply and Installation of Power Supply, Uninterruptable for New Block Redevelopment Projects of Queen Man- Hospital and Cranlham Hospital. The reference ID of the tender is 73496091 and it is closing on 16 Nov 2022.

Tender Details

  • Country: Hong Kong
  • Summary: Supply and Installation of Power Supply, Uninterruptable for New Block Redevelopment Projects of Queen Man- Hospital and Cranlham Hospital
  • HKT Ref No: 73496091
  • Deadline: 16 Nov 2022
  • Financier: Self Financed
  • Purchaser Ownership: Government
  • Tender Value: Refer Document
  • Notice Type: Tender
  • Document Ref. No.: HKWC-T012/21(P-HKWC)
  • Purchaser's Detail:
    Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details.
  • Description:
  • Tenders are invited for Supply and Installation of Power Supply, Uninterruptable for New Block Redevelopment Projects of Queen Man- Hospital and Cranlham Hospital, Hong Kong West Cluster, Hospital Authority. 1 Introduction 1.1 The tender calls for the supply, delivery and installation, and Testing and Commissioning for four (4) complete sets of Uninterruptible Power Supply (UPS), Isolation Transformer, Battery c/w Battery Monitoring System for Hospital Authority. - 2 complete sets for Queen Mary Hospital - 2 complete sets for Grantham Hospital M Part A Equipment Specification 2 General Description 2.1 Four (4) complete sets of Uninterruptible Power Supply (UPS) shall include: M 2.1.1 Uninterruptible Power Supply: 4 sets of online double conversion modular UPS. M 2.1.2 Isolation Transformer: 4 sets M 2.1.3 Battery completed with Battery Monitoring System: 4 sets M 2.1.4 Electrical and Others:  External Make-Before-Break Maintenance Bypass Panel (EMBP): 4 sets M 3 Specification for Uninterruptible Power Supply (UPS) (Refer to Clause 2.1.1) Each set of UPS shall have the following features: M 3.1 Design 3.1.1 The UPS shall be designed and operated in Modular Redundancy Architecture. It shall be made up of one or more physically detachable equipment modules or cabinets, of drawout type and removable from the front of the UPS system. Tenderers shall provide relevant information / specify the requirements for equipment on offer in EOI return for M consideration. The Indicative UPS Schematic Diagram Drawing would be provided in tender stage. 3.1.2 The UPS shall be dual feed input. M 3.1.3 The UPS shall be supplied with enough power module so that it can support design load of following power rating in N+1 redundancy. QMH: 140kW GH: 200kW M 3.1.4 Input Power Factor 0.99 Output Power Factor = 1 M 3.1.5 The control module and all power modules of the UPS Unit shall be housed in single equipment rack. M 3.1.6 Expandability: In case future power expansion is needed, UPS Frame of additional (minimum following power rating per frame and up to 4 frames) shall be able to install to expand the UPS power rating without power interruption to supporting load. QMH: 140kW GH: 200kW M 3.1.7 Any installation or system reconfiguration required for the expansion shall not affect the live operations of the modular UPS. There is required to put the UPS onto bypass mode for expansion. M 3.1.8 The overall size of the UPS frame should not be larger than 900*2100*1200 (W*H*D in mm) per frame in all directions M 3.1.9 The availability of the system shall not be less than 99.9995%. M 3.1.10 The current rating of the inter-battery cables shall be greater than 1.5x of the nominal maximum of charge / discharge current. M 3.1.11 The rectifier / charger unit shall be provided with an input isolating switch / circuit breaker. The rectifier / charger unit shall have protection to prevent the battery from over-charging due to battery charger / rectifier fault. An adjustable battery current limiting device shall limit the battery recharge current to the maximum value recommended by the battery manufacturer. M The rectifier / charger unit shall be able to automatically adjust the battery float charge voltage based on temperature variation in accordance with battery manufacturer-s recommendation. The charging current shall be adjustable from 5% to 30% so as to limit the total input current when the battery has been discharged. 3.2 Power Module: 3.2.1 Power Rating: ≥ 25kW per power module The power modules shall be hot-swappable such that replacement of the faulty modules can be carried out on-line without any output interruption. M 3.2.2 Features: 3.2.2.1 Soft Start and with Internal Backfeed Protection. M 3.2.2.2 UPS efficiency in double conversion mode ≥ 97% and shall be able to maximize to 99% with energy save mode. (Self-declare is not accepted, Manufacturer written literature with supporting data required) M 3.2.3 Input Voltage: Three-phase 380V+N 50/60Hz M 3.2.4 Input Voltage Range (V): 340 - 437 or wider M 3.2.5 Input Frequency : 40 to 70 Hz or wider M 3.2.6 Output Voltage: Three-phase 380V+N 50/60Hz M 3.2.7 Total voltage harmonic distortion: M 3.2.7.1 ≤ 1% (100% linear load) M 3.2.7.2 ≤ 5% (100% non-linear load) M 3.2.8 Overload on inverter: M 3.2.8.1 1 min from 125% M 3.2.8.2 10 seconds from 150% M 3.2.9 Permitted load power factor: 0.8 lagging to 0.8 leading M 3.2.10 Efficiency in double conversion On-Line mode ≥ 97% Efficiency in Energy Saver Mode maximize to 99% M 3.2.11 Energy efficiency of the UPS system shall not be less than 92% at 50% rated load. M 3.3 Internal Static Bypass Switch (SBP) 3.3.1 A full rating internal SBP shall be equipped for the UPS M 3.3.2 The SBP module shall be hot swappable M 3.3.3 The SBP shall be fuse and back feed protected M 3.3.4 Overload on bypass: M 3.3.4.1 110% continuous M 3.3.4.2 1000% 20 milliseconds M 3.4 UPS centralized communication module (UCM) 3.4.1 The UCM shall be hot swappable M 3.5 Battery Connection: 3.5.1 The UPS shall be ready for connecting to VRLA or Li-ion Battery without any hardware modification nor additional cost. M 3.6 Connectivity 3.6.1 Each UPS system shall equip with Simple Network Management Protocol (SNMP v1 or v2) network adaptor for remote monitoring through Ethernet network. M 3.6.2 The UPS shall support TCP/IP and SNMP traps protocols for remote monitoring. The network interface shall be Ethernet 10/100 Base T standard with RJ45 jack. M 3.6.3 Each UPS system shall equip with: M 3.6.3.1 Mini-slot ports for optional cards M 3.6.3.2 Device USB and/or Host USB M 3.6.3.3 RS-232/RS-485/USB service port M 3.6.3.4 Relay output M 3.6.3.5 Output terminal/ connection for dummy load test (full load) and battery discharge test M 3.6.3.6 Building alarm inputs M 3.6.3.7 Emergency Power-Off (EPO) button status M 3.6.4 UPS system shall provide interfacing connections (e.g. SNMP, Modbus, BACnet) to Central Control and Monitoring System (CCMS), including but not be limited to: - UPS status (on/off/fault) - Static bypass status - Internal static transfer switch status (not applicable to the UPS for GH) - Common fault alarm - Input voltage(s) - Input current(s) - Input frequency - Input power - Output voltage(s) - Output current(s) - Output frequency - Output power - Output load rate (%) (not applicable to the UPS for GH) - Bypass voltage (not applicable to the UPS for GH) - Bypass current (not applicable to the UPS for GH) - Battery voltage - Battery temperature - UPS input power supply failure - UPS system failure - Battery system failure The tenderer shall be fully responsible for liaison and coordination works with relevant parties including the Main Contractor and other Mechanical and Electrical (M&E) contractors for exact requirements and interfacing arrangement. M 3.7 Standard Compliance Equipment offered shall comply with: M 3.7.1 Latest version of General Technical Specification for Uninterruptible Power Supply (UPS), issued by Electrical and Mechanical Services Department (EMSD) M 3.7.2 Safety certification: IEC 62040-1 M 3.7.3 Electromagnetic compatibility (EMC) certification: IEC 62040-2 M 3.7.4 Performance certification: IEC 62040-3 M Etc.
  • Documents:

 Tender Notice

If you are registered member, kindly login to view full details of this tender notice:

CLICK HERE TO LOGIN

Supply and Installation of Power Supply, Uninterruptable for New Block Redevelopment Projects of Queen Man- Hospital and Cranlham Hospital - Hongkong Tender

The HOSPITAL AUTHORITY (HA), a Government sector organization in Hong Kong, has announced a new tender for Supply and Installation of Power Supply, Uninterruptable for New Block Redevelopment Projects of Queen Man- Hospital and Cranlham Hospital. This tender is published on HongkongTenders under HKT Ref No: 73496091 and is categorized as a Tender. Interested and eligible suppliers are invited to participate by reviewing the tender documents and submitting their bids before the deadline on 2022-11-16.

The estimated tender value is Refer Document, and full details, including technical specifications and submission requirements, are provided in the official tender documents. Ensure all submissions meet the criteria outlined to be considered for evaluation.

HongkongTenders Features

HongkongTenders Features

Fresh and verified Tenders from Hongkong. Find, search and filter Tenders/Call for bids/RFIs/RFPs/RFQs/Auctions published by the government, public sector undertakings (PSUs) and private entities.

  • 1,000+ Tenders
  • Verified Tenders Only
  • New Tenders Every Day
  • Tenders Result Data
  • Archive & Historical Tenders Access
  • Consultants for RFI/RFP/RFQ
  • Tender Notifications & Alerts
  • Search, Sort, and Filter Tenders
  • Bidding Assistance & Consulting
  • Customer Support
  • Publish your Tenders
  • Export data to Excel
  • API for Tender Data
  • Tender Documents
Tender Experts

Get A Call From Tender Experts

Fill out the form below and you will receive a call from us within 24 hours.

Thank You for Contacting HongkongTenders !!
Email Id is already exist !!
Captcha Image
Invalid Captcha !

Get FREE SAMPLE TENDERS from Hongkong in your email inbox.

  Chat with us