• Register
  • Login
  • Subscribe
  • Contact Us

Supply and Installation of Video Systems, Operating Room for Pamela Youde Nethersole Eastern Hospital Hong Kong East Cluster

HongkongTenders notice for Supply and Installation of Video Systems, Operating Room for Pamela Youde Nethersole Eastern Hospital Hong Kong East Cluster. The reference ID of the tender is 74698716 and it is closing on 30 Nov 2022.

Tender Details

  • Country: Hong Kong
  • Summary: Supply and Installation of Video Systems, Operating Room for Pamela Youde Nethersole Eastern Hospital Hong Kong East Cluster
  • HKT Ref No: 74698716
  • Deadline: 30 Nov 2022
  • Financier: Self Financed
  • Purchaser Ownership: Government
  • Tender Value: Refer Document
  • Notice Type: Tender
  • Document Ref. No.: 1110450513
  • Purchaser's Detail:
    Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details. Login to see full purchaser details.
  • Description:
  • Expression of Interest are invited for Supply and Installation of Video Systems, Operating Room for Pamela Youde Nethersole Eastern Hospital Hong Kong East Cluster, Hospital Authority 1. General Requirements 1.1 This tender calls for the supply and installation of 1 set of Endolaparoscopic Video System for PYNEH C8 OT Room 3 including Video Laparoscopes and Central Control of Medical equipment that could be seamlessly integrated with AV system with in-room video routing as well as conferencing system connecting C8 OT Room 3 and Minimal Access Surgery Training Centre (MASTC). (M) 1.2 The proposed system shall integrate equipment and support systems to create the ideal OR environment for efficient, comfortable surgery. Control of all aspects of the OR is centralized using convenient touch screen, providing advanced external communication and access to any information, whether images or videos. (M) 1.3 The proposed video endolaparoscopic system shall be able to connect with AV system to be installed in the same operating theatre. (M) 1.4 The Video Endolaparoscopic System set in PYNEH C8 OT Room 3 shall include the following: (M) EOI Ref.: 1110450513 Yes No (provide details) (Please tick as appropriate) - 10 - 1.4.1 2 sets of 4K 3D Video System Center (M) 1.4.2 2 sets of 5-LED IR Light Source (M) 1.4.3 1 set of Autoclavable 4K Continuous AF Camera Head (M) 1.4.4 2 sets of HD Ultra-Lightweight Urology Camera Head (M) 1.4.5 2 sets of CO2 Insufflator (M) 1.4.6 2 sets of Gas Pre-heater for insufflator (M) 1.4.7 4 sets of 4K 3D 32” Medical Grade LCD Monitors with HDR function (M) 1.4.8 2 sets of HD Image Management Hub (M) 1.4.9 2 sets of 10mm 30Deg HD Video-laparoscope (M) 1.4.10 2 sets of Endoscopic Camera System Centre (M) 1.4.11 1 set of Motorized Spiral Enteroscopy Endoscopic Video System Set (M) 1.4.12 2 sets of Endoscopic CO2 Regulation Unit (M) 1.4.13 1 set of Ultrasonic Generator (M) 1.4.14 1 set of Medical Controller Unit (M) 1.4.15 1 set of OT Central Video Matrix (M) 2. 4K 3D Video System Center x 2 sets 2.1 Shall be able to reproduce 4K 2D or 4K 3D image when used in conjunction with 4K camera head or 4K 2D or 4K 3D video laparoscope. (M) 2.2 Shall be compatible with flexible endoscopes for a multitude of procedures. (M) 2.3 Shall be compatible with 4K camera head with ICG compatibility and 4K 3D video-laparoscope. (M) EOI Ref.: 1110450513 Yes No (provide details) (Please tick as appropriate) - 11 - 2.4 Able to enable fluorescence imaging when used in conjunction with specific videoscope and camera head. (M) 2.5 Reproduction of digital chromoendoscopy feature when used in conjunction with compatible endoscope including Cystoscopic videoscope, ENT videoscope, Ureteroscopic Videoscope, 2D and 3D video laparoscope. (M) 2.6 The camera system shall be able to connect with at least 5 types of flexible rhino-laryngo videoscopes. (M) 2.7 The camera system shall be able to connect with flexible videoscope with pistol-grip handle design to minimize strain and maximize performance. (M) 2.8 The proposed system shall be able to connect to existing laparoscopic camera heads, cysto-videoscopes, ENT rhinolaryngo videoscope, uretero-videoscopes, 2D and 3D video laparoscopes. Otherwise the tenderer shall provide equivalent equipment to fulfill surgical needs. (M) 2.9 Dye-less or digital chromoendoscopy by hardware and software mechanisms shall be available. (M) 2.10 Shall be completed with all necessary accessories, which are essential for the normal operation of the equipment. (M) 2.11 The proposed camera system shall be able to use with HD flexible tip video laparoscope. (M) 2.12 Shall be able to provide 4K Imaging Capability to provide best image quality for flexible tip videoscope, rigid endoscopes and 3D videoscopes. (M) 2.13 The console should be controlled by touch panel/touchpad//keyboard. (M) 2.14 USB memory port enables convenient digital-to-digital recording of still images into portable memory. (M) 2.15 The offered camera system shall allow encryption setting for portable memory to ensure data security. (M) 2.16 USB memory port shall be able to read and write an encrypted portable memory. (M) EOI Ref.: 1110450513 Yes No (provide details) (Please tick as appropriate) - 12 - 2.17 High dynamic range function could be set to on/ off. When switched on, the contrast could be set to low/ medium/ high to cope with difference procedure and surgical situation. (M) 2.18 Signal output: 12G-SDI x2, Quad 3G-SDIx1, 3G-SDIx2, 3GSDI (Side by side) x1, HD-SDI x1 or more. (M) 2.19 Video output shall be compatible with display monitors and video recorders offered. (M) 2.20 User interface: Touchscreen / Touchpad / Keyboard with Mouse (M) 2.21 Shall have Image Enhancement Features: (M) 2.21.1 White balance (M) 2.21.2 Colour tone adjustment (M) 2.21.3 Contrast adjustment (M) 2.21.4 Image sharpness / structures enhancement (M) 2.21.5 Zoom / Image enlargement (M) 2.21.6 Image freeze (M) 2.21.7 Automatic brightness adjustment to balance the shadow and over-exposure. (M) 2.21.8 Digital chromoendoscopy feature to improve the visibility of blood vessels and mucosal structures without the need for tissue staining. (M) 2.21.9 Automatic gain control (AGC) / Automatic light control to automatically control the light intensity by distance. (M) 2.22 IR observation, which is one of the optical-digital observations using the infrared LED light source, shall be available. (M) 2.23 Functions shall be able to be assigned to custom switches in user presets. (M) EOI Ref.: 1110450513 Yes No (provide details) (Please tick as appropriate) - 13 - 2.24 Remote switches on endoscopes or camera head shall be available. (M) 2.25 Foot switches shall be available. (M) 2.26 Keyboard custom key shall be available. (M) 2.27 Custom buttons shall be available. (M) 2.28 The patient data shall be able to be displayed on the monitor using the keyboard. (M) 2.29 The recording state of the ancillary equipment shall be able to be displayed on the monitor. (M) 2.30 Portable memory Format: TIFF and JPEG (1/10) or more (M) 2.31 The offered camera system shall have at least 20 user settings (M) 2.32 The camera system shall have memory of white balance setting with the compatible endoscopes. (M) 3 5-LED IR Light Source x 2 sets 3.1 The examination lamp should consist of 5 LEDs: Red, Orange, Yellow, Violet, and Infrared. (M) 3.2 It can automatically adjust light intensity to achieve ideal illumination for observation by LED drive current control. (M) 3.3 Shall be able to provide white light imaging, digital chromoendoscopy feature to improve the visibility of blood vessels and mucosal structures without the need for tissue staining. (M) 3.4 Illumination 3.4.1 Brightness of LED should be equivalent to Xenon 300W or above (M) 3.5 Cooling: Forced-air cooling (M) 3.6 Brightness mode: Auto or Manual (M) EOI Ref.: 1110450513 Yes No (provide details) (Please tick as appropriate) - 14 - 3.7 The LED Light Source shall be able to produce Infra-Red light for Indocyanine Green (ICG) observation. The LED Light Source with IRI (ICG) function shall be compatible with the 3D Video Processor. (M) 3.8 There shall be only one light source, which included the infrared imaging and white light imaging, for easier maintenance and operation. (M) 3.9 The light source shall be laser-free for safety, ease of maintenance and low running cost. (M) 3.10 The LED Light Source shall be able to switch from White Light image to Infra-Red light image easily by simply pressing the button on the front panel or the Camera Head. (M) 3.11 Average lamp life: Approximately at least 5000 hours Examination Lamp. (M) 3.12 Optical-digital observation: capable of digital chromoendoscopy observation and Indocyanine Green (ICG) observation. (M) 3.13 Settings (except the observation mode) are stored, even the LED Light Source is switched OFF. (M) 3.14 Observation mode: Normal light observation mode, NBI observation, IRI observation mode (M) 3.15 Brightness adjustment method: LED drive current control (M) 3.16 Exposure: 17 steps or more (M) 4. 4K Continuous AF Camera Head x 1 set 4.1 The 4K Camera Head shall be used in conjunction with Video System Processor for laparoscopic or endoscopic procedures. (M) 4.2 The camera head shall be able to reproduce 4K HDR image. (M) 4.3 The camera head shall have Extended Depth of Field. (M) 4.4 Observation: digital chromoendoscopy (M) 4.5 Indocyanine Green (ICG) compatible (M) EOI Ref.: 1110450513 Yes No (provide details) (Please tick as appropriate) - 15 - 4.6 Focal Length f = 19.7mm (M) 4.7 Cable dimension: 3m or longer (M) 4.8 High level disinfection method: Washer Disinfector (M) 4.9 Sterilization method: Autoclave (withstand 134 degC) (M) 4.10 The camera head shall be adaptable to flexible fiberscope, laparoscope or rigid scopes for urology, gynecology, ENT and orthopedics procedures. (M) 4.11 The camera head shall have a continuous autofocus function. (M) 4.12 The camera head shall have a button to activate single autofocus function and active continuous autofocus function. (M) 4.13 Once the continuous autofocus function is activated, the camera head shall automatically focus at the central part of the screen and no manipulation is needed. (M) 4.14 The camera head weight should not exceed 270g (M) 4.15 The camera head shall have the below functions: (M) 4.15.1 NBI observation mode or equivalent picture enhanced observation mode (M) 4.15.2 Electronic Shutter Function (M) 4.16 Degree of protection against electronic shock: Type CF (Entire Camera Head) (M) 4.17 Pickup System: CMOS image sensor or equivalent (M) 4.18 Shall be completed with all necessary accessories, which are essential for the normal operation of the equipment. (M) 5. HD Ultr
  • Documents:

 Tender Notice

If you are registered member, kindly login to view full details of this tender notice:

CLICK HERE TO LOGIN

Supply and Installation of Video Systems, Operating Room for Pamela Youde Nethersole Eastern Hospital Hong Kong East Cluster - Hongkong Tender

The HOSPITAL AUTHORITY, a Government sector organization in Hong Kong, has announced a new tender for Supply and Installation of Video Systems, Operating Room for Pamela Youde Nethersole Eastern Hospital Hong Kong East Cluster. This tender is published on HongkongTenders under HKT Ref No: 74698716 and is categorized as a Tender. Interested and eligible suppliers are invited to participate by reviewing the tender documents and submitting their bids before the deadline on 2022-11-30.

The estimated tender value is Refer Document, and full details, including technical specifications and submission requirements, are provided in the official tender documents. Ensure all submissions meet the criteria outlined to be considered for evaluation.

HongkongTenders Features

HongkongTenders Features

Fresh and verified Tenders from Hongkong. Find, search and filter Tenders/Call for bids/RFIs/RFPs/RFQs/Auctions published by the government, public sector undertakings (PSUs) and private entities.

  • 1,000+ Tenders
  • Verified Tenders Only
  • New Tenders Every Day
  • Tenders Result Data
  • Archive & Historical Tenders Access
  • Consultants for RFI/RFP/RFQ
  • Tender Notifications & Alerts
  • Search, Sort, and Filter Tenders
  • Bidding Assistance & Consulting
  • Customer Support
  • Publish your Tenders
  • Export data to Excel
  • API for Tender Data
  • Tender Documents
Tender Experts

Get A Call From Tender Experts

Fill out the form below and you will receive a call from us within 24 hours.

Thank You for Contacting HongkongTenders !!
Email Id is already exist !!
Captcha Image
Invalid Captcha !

Get FREE SAMPLE TENDERS from Hongkong in your email inbox.

  Chat with us